ADR-0013: Control Interface¶
Note
How anything outside the shell process tells it to do something: the command line, a keyboard shortcut, the KWin script that reports fullscreen windows. The shell owns one session-bus name and exports a small D-Bus interface; the command line is a thin client of it. Accepted 2026-10-28 (Option B).
Context¶
- The shell is one process with one loop (ADR-0003 Process Model). It needs commands from outside: reload, quit, show or hide a surface, call a module action, report status.
- ADR-0012 (accepted) has a KWin script report fullscreen windows to the shell. A KWin script can call a D-Bus method (
callDBus(service, path, interface, method, args, callback), asynchronous) and the scripting page documents no way to run a process (KWin scripting API, read 2026-10-28). So the shell must offer a D-Bus method for the script, whatever else it offers. - A keyboard shortcut for a launcher can be a KDE custom shortcut that runs a command; that command must start fast.
- Measured on this machine (2026-10-28, Python 3.14.8, median of 9 runs): a bare Python start is 7.6 ms; importing
argparse,json,socketandosbrings it to 16.7 ms; a stdlib Unix-socket connect attempt takes 13.8 ms;jeepney(pure Python, 0.9.0) connecting to the session bus and making one call takes 20.0 ms; importingjsonschemaalone takes 57.5 ms.dbus-fast5.2.0 was then installed in a scratch folder (not on the system) and tested the same day. Importingdbus_fast.aiotakes 54.3 ms and adbus-fastclient making one call takes 53.2 ms, against 21.0 ms for thejeepneyclient and 1.5 ms forbusctl --user callas a reference. A test service on the session bus, written withdbus-fast, exported a method returning two values, a method that raises a named D-Bus error, a method taking an array of strings, a read-only property that emits changes, and a signal;busctl introspectlisted them all,busctl callreached them,busctl monitorsaw the signal, and a second process requesting the same name withDO_NOT_QUEUEgotEXISTS. Sodbus-fastis fit to export the interface; as a command-line client its import cost makesjeepneythe better choice.
Options¶
Option A — A Unix Socket with JSON Lines, and D-Bus Only for the KWin Script¶
- For: a client with no dependencies; trivial to script (
nc -U). - Against: two mechanisms, two front-ends, two security stories; the socket does nothing the D-Bus interface cannot do.
Option B — One D-Bus Interface for Everything (Recommended)¶
The shell requests a bus name on the session bus and exports one object. The command line, the KWin script, busctl, qdbus and shortcut commands all call it. The command line is a thin client.
- For: one front-end and one set of commands; the KWin script needs it anyway; introspectable (
busctl introspect); signals for free (events); the bus enforces that only the same user's processes connect; measured client cost is close to the socket's (20 ms against 14 ms). - Against: needs the session bus (always present in a Plasma session); the CLI needs a small D-Bus client (
jeepney, the named fallback in ADR-0009 D-Bus Client Library, is 21 ms againstdbus-fast's 53 ms); a name on the bus must be chosen. A shortcut command can also callbusctl --user calldirectly, which took 1.5 ms.
Option C — Both, behind One Command Table¶
- For: a CLI that works with no bus.
- Against: the cost of A for a case that does not arise in the target session.
Decision¶
Option B (maintainer, 2026-10-28, "yes" to the recommendation): one D-Bus interface for everything, with the bus name io.github.mindderivative.TesseraeShell and the command tesserae-shell. The lock file stays for the single-instance rule; there is no control socket.
Consequences¶
- The shell's D-Bus service thread (shared, ADR-0009 D-Bus Client Library) also exports the shell's own object. ADR-0009 had named
bus.exportand name requests as later work; this makes them v1 work. - Shell Start and Stop uses the D-Bus interface where it said control socket, and the lock file stays for the single-instance rule. The runtime directory holds the lock file only.
- The bus name is a project identifier that must be chosen and kept (IPC and CLI > The bus name).
- The interface has no method that evaluates code or reads files (IPC and CLI > Security).
Update 2026-10-29¶
A test showed that a KWin script's callDBus cannot send an array of strings as as; it sends av. FullscreenState therefore takes one string holding a JSON array (IPC and CLI > The interface, KWin Integration). The accepted decision is unchanged.
Links¶
IPC and CLI · ADR-0009 D-Bus Client Library · ADR-0012 Keeping the Shell Above Plasma Panels · 30 Decisions