Skip to content

Process Model and Threading

Note

One process, one tre event loop on the main thread (ADR-0003 Process Model). Everything that touches a window or node, every TEL evaluation and every module callback runs there, between frames. Everything that waits (D-Bus, files, sockets, timers of module work) runs on other threads and hands finished values back with LoopHandle.call_soon. Decided: the single process and the thread rule. Proposed in this note: the thread inventory, coalescing, the watchdog and the lifecycle.

What Tre Guarantees

From the tre threading guide (read 2026-10-25):

  • tre runs on the one thread that created the App. Its windows, nodes, listeners, animation completions and draw callbacks live and run there once App.run() starts.
  • App.thread_handle() returns a LoopHandle, the one tre object any thread may use. call_soon(fn) queues fn for the loop thread and wakes the loop, even when idle.
  • Callbacks run in the order queued, at the top of the next frame, where they can touch windows and nodes as a listener can. One that raises is logged and does not stop the loop or the callbacks after it.
  • window.after(ms, fn) and window.every(ms, fn) run something later on the loop thread; call_soon has no delay.
  • A call_soon callback runs between frames, so it should only apply a finished result.
  • App.run() raises RuntimeError when no window is registered, and ends when every window has closed (App reference).

Threads

Thread Runs Touches nodes Crosses into the loop by
Loop (main) tre App.run(); surface manager; shell model; TEL evaluation; module host calls (start, stop, reload); registry updates Yes n/a
Module threads A module's blocking work: D-Bus, sockets, polling, files, decoding Never The shell's send entry point, which uses call_soon
Config watcher Waiting for file changes; reading and parsing a changed file Never call_soon with a finished result
Service thread An asyncio event loop, shared by modules, holding the session and system bus connections (dbus-fast, ADR-0009 D-Bus Client Library); it also receives calls on the shell's own D-Bus interface (IPC and CLI > Threading, ADR-0013 Control Interface) Never The same send entry point
Signal watcher Reads a socketpair fed by signal.set_wakeup_fd and calls handle.stop() on SIGTERM or SIGINT Never LoopHandle.stop() (TRE-REQ-005 Keep-Alive and Loop Stop)
Watchdog Checks that the loop is still ticking Never Logs, and asks the supervisor to restart if the loop is stuck

tre also runs its own threads internally (the layer surface connection, for example). They are tre's concern; the shell sees only the loop thread and its callbacks.

The Rules

  1. Nothing blocking on the loop. No D-Bus call, file read, subprocess or network call on the loop thread (ADR-0003 Process Model).
  2. Only the loop touches nodes. A thread that wants a change sends a value; it never holds a node.
  3. Only finished data crosses. A worker reads, parses or decodes; the loop applies.
  4. Python is never in layout or paint (Vault Reference > Layering principle). TEL expressions and module callbacks run in callbacks between frames and are short.
  5. Every module spec states its thread and how it crosses into the loop (Vault Reference > Layering principle).

Handing a Value to the Loop (Proposed)

A module thread calls the shell's send entry point (the hand-off decided in ADR-0007 Shell UI Layer > Module data reaches the view through shell entry points (2026-10-25)). The entry point must be safe from any thread. Proposed behaviour:

  • Coalesce. The entry point writes the value into a pending map keyed by module and key, then queues one call_soon flush if none is queued. A module that sends the volume 200 times a second leaves only the latest in the map, and the loop applies it once per turn.
  • Order. Values from one module keep their order per key. Across keys, the flush applies them together in one turn, so a view never shows half an update.
  • No blocking. The send never waits for the loop.
  • Conversion (HEX to RGBA and the like) happens in the flush on the loop, or in the send on the module thread if it is pure; decide in the Python API spec.
sequenceDiagram
    participant M as Module thread
    participant S as Send entry point
    participant L as Loop thread
    participant T as TEL scope
    participant R as tre
    M->>S: send("time", "14:05")
    S->>S: store in pending map
    S->>L: call_soon(flush) if none queued
    L->>S: flush at top of next frame
    L->>T: update names that changed
    T->>L: re-evaluate affected expressions
    L->>R: node.set(text=...)
    R->>R: draw frame

Lifecycle (Proposed)

stateDiagram-v2
    [*] --> Loading: process starts
    Loading --> Running: model built, windows open, modules started
    Loading --> Failed: shell file refused
    Running --> Reloading: file changed
    Reloading --> Running: applied (or old state kept on error)
    Running --> Stopping: quit or signal
    Stopping --> [*]: modules stopped, windows closed, registry written
    Failed --> [*]
  • Loading. Read the config directory, parse, validate, follow imports, check or write the registry, resolve references, read outputs, build the model. Errors stop here with file:line:column.
  • Running. Modules start after the model is built, so a value that arrives before its surface exists is kept in the store.
  • Reloading. A watcher thread reads and parses a changed file; the loop applies it. A bad file leaves the old state and logs an error (Data Flow > Hot reload).
  • Stopping. A quit signal reaches a watcher thread through signal.set_wakeup_fd, which calls LoopHandle.stop(). stop() closes every window without a veto (each hears closed with reason "stopped") and run() returns. The shell then calls each module's stop, joins its threads with a timeout, and writes the registry, on the main thread. Python signal handlers do not run on an idle loop, which is why the wakeup-fd path is used (TRE-REQ-005 Keep-Alive and Loop Stop). Until that ships, ending the loop means closing every window.
  • No windows: stay idle (decided 2026-10-26). If every monitor is set to "none", or no output is present, the shell does not exit; it waits and reacts when an output is added (Data Flow > Monitor hot-plug). What tre can do is in No windows: what tre offers.

No Windows: what Tre Offers

The tre session answered over the mailbox on 2026-10-26, from the 0.5.8 source and runs on a headless sway (information only; no issue filed). A peer's claim is a lead; the first two facts match tre's documentation that run() raises with zero windows.

Finding Detail
No keep-alive mode App.run() raises RuntimeError with zero registered windows, and the platform loop ends when no window and no layer surface is left
Re-running works, but not asleep Calling run() again after it returned works. Output events do not fire while run() is not active, and an output plugged in between runs is not reported as output_added; it is just the starting state. A restart-on-demand design must diff App.outputs() (works any time) against what it knew
A hidden layer surface fails A 1x1 LayerWindow (background layer, no anchor, input region [], keyboard none) keeps the loop alive, but it is bound to an output. When that output is unplugged it closes with reason output_removed and the run ends in the same turn, even if a listener adds a new one. It fails exactly when the last or current output is removed
A 1x1 ordinary window survives An ordinary toplevel Window(width=1, height=1) survived unplugging its output, then the last output, then plugging a new one: output events and call_soon kept working with zero outputs. Cost: it is a visible 1x1 toplevel (a task-list entry, space on a tiling compositor). Hiding it (Window.minimize()) is untested; not tested on KWin
Suggested engine addition An opt-in keep-alive, for example App.run(keep_alive=True): no error with zero windows, no exit when empty, output watch started at loop start. It needs a way to end the loop. A LoopHandle stop does not exist today; the loop ends only when every window closes. Rough size: about 60 to 100 lines plus tests and docs, low risk because it is opt-in

Warning

Blocked by TRE-REQ-005 Keep-Alive and Loop Stop Option A was chosen by the maintainer on 2026-10-26: the opt-in keep-alive and a LoopHandle stop. tre released it in 0.5.9 on 2026-10-27 as App.run(keep_alive=True) and LoopHandle.stop() (TRE-REQ-005 Keep-Alive and Loop Stop). The stopgap B is no longer needed.

Options for the shell:

Option Description Verdict
A. Ask tre for the opt-in keep-alive and a LoopHandle stop The clean answer; the stop is needed for shutdown anyway Recommended. Small, opt-in, low risk
B. A hidden 1x1 ordinary window as a stopgap Worked today (not on KWin) No longer needed: option A shipped in tre 0.5.9
C. Restart on demand, diffing App.outputs() Cannot wake on a hot-plug Not suitable for "react when an output is added"

The shell also needs a clean way to end the loop on quit. Today that means closing every window, which is not possible with zero windows. A LoopHandle stop would cover both (Process Model and Threading > Lifecycle (proposed)).

Failure and Recovery

Failure Effect Handling (proposed)
A module raises in start or a callback That module is marked failed Log with the module name and UID; surfaces keep their last values or fall back; other modules continue
A module thread dies No more values from it The module host sees no heartbeat or a thread helper reports the exception; log; optional restart
A module blocks the loop Every surface freezes (ADR-0003 Process Model > Consequences) Watchdog sees no ticks; logs the stall; with a supervisor, restart the process
Wayland connection lost tre windows close Process exits; supervisor restarts it
A bad shell file on reload New state refused Keep the old state; log an error with position
A bad module .py on reload New code refused Keep the old instance running; log the error (ADR-0007 Shell UI Layer > Events and module reload (2026-10-26))

The loop cannot interrupt itself, so detecting a blocked loop needs a separate watchdog thread that reads a counter the loop bumps from a timer (window.every). A supervisor outside the process is the only way to recover from a hard hang. Both are proposals; 60 Quality owns the final design.

Caution

Single point of failure One hung Python callback blocks every surface (ADR-0003 Process Model). The mitigation is conventions (rule 1), tooling (the send entry point, thread helpers), a watchdog and a supervisor. None of those is built.

Performance Notes

  • A frame at 60 Hz is about 16.7 ms. call_soon callbacks and TEL evaluations share that time with layout and paint. Budgets are set in 60 Quality.
  • tre documents that an idle surface draws no frames and wakes the loop only for its own timers (TRE-REQ-001 Layer Surface Window). On the unreleased keep-alive branch, tre measured 0.01 s of CPU in 5 s with zero windows, and reports one wake source it does not control: the D-Bus library's worker, about 2 wake-ups a second, behind the OS-preference watcher every tre app has. The shell's own D-Bus service thread (ADR-0009 D-Bus Client Library) adds its own idle cost, so the idle goal (Goals and Non-Goals G4) should be measured with the service thread running. #needs-verification The shell must not add a timer that wakes the loop without a reason: a clock updates once a second, not every frame.
  • The shared GIL means a CPU-heavy module thread slows the loop. Heavy work belongs in a subprocess or native code; the module contract says so (42 Python API, to write).

Open Questions

  • Who owns module threads? Context: options. A: each module starts and owns its threads, and the shell gives a helper that catches and logs thread exceptions (flexible, simple contract). B: the shell runs a shared asyncio thread for services and modules are coroutines (less thread code, forces async on module authors). C: a shell thread pool for module work. Recommendation: A, with B available as an optional shared service thread for D-Bus.
  • D-Bus client library. dbus-fast on a shared asyncio service thread, jeepney as the fallback (maintainer, 2026-10-26, ADR-0009 D-Bus Client Library).
  • Does registry I/O and the UID write run on the loop or on a single writer thread? Context: Config Discovery and Registry > The registry file proposes one writer thread, one write per 500 ms (ADR-0007 Shell UI Layer > Open Items). Recommendation: the single writer thread.
  • Does a supervisor ship in v1 or later? Context: only a supervisor outside the process recovers from a hard hang; the watchdog alone logs it, and neither is built. Recommendation: later; the v1 watchdog is enough.
  • No windows policy: stay idle (maintainer, 2026-10-26).
  • No windows mechanism. Option A, chosen 2026-10-26 and released in tre 0.5.9 on 2026-10-27: App.run(keep_alive=True) and LoopHandle.stop() (TRE-REQ-005 Keep-Alive and Loop Stop). The shell requires tre 0.5.9 or later.
  • Do value conversions run in the send or in the flush? Context: HEX to RGBA and the like can run on the module thread if pure, or on the loop in the flush. Recommendation: convert in the flush on the loop, which keeps module threads free of shell types; decide finally in the Python API spec.