Skip to content

Logging

Tesserae logs with loguru. It uses loguru's shared logger and adds no output of its own, so its messages go wherever your app's loguru setup sends them. With no setup at all, that's loguru's default output on stderr, so you see them straight away.

Setting up the console

configure_logging() is a one-call setup for app.py:

from loguru import logger

from tess_ui import App, configure_logging

configure_logging()          # INFO and above, Tesserae's format
# configure_logging("DEBUG") # also shows loads, screen switches, tracebacks

logger.info("starting")      # your own messages use the same logger

The output looks like:

12:48:27.553 | INFO     | tess_ui.spec.watch - reloaded /path/to/Home_View.tdl

configure_logging replaces loguru's default stderr handler and leaves any handler you added yourself. Call it once: each call adds a handler, so a second call prints every message twice (logger.remove(handler_id) removes one). It takes level, sink (anything logger.add accepts: a stream, a file path, a function) and format (tess_ui.log.DEFAULT_FORMAT by default), and returns the handler id.

What Tesserae logs

Level Message
DEBUG a screen shown (app.show), the traceback of a failed hot reload
INFO hot reload started (hot reload on: watching N screen(s) and M theme/stylesheet file(s)), and what it watches; hot reload off in a built app (there are no source files); a screen it does not watch; each view reloaded; each theme or stylesheet file applied; the app switching between light and dark or between standard and high contrast
WARNING a Link whose href is refused (only http, https, mailto and tel are opened); a property the user edits given one bare name that cannot be written back (Main_View.tdl:5:42: Checkbox checked is given 'flag', which is a ViewModel attribute that is not a Signal: the user's edit is not written back (one-way)), once for each place in a file; Python warnings such as FontFallbackWarning, when configure_logging captures them (below)
ERROR a hot reload that failed, naming the file and the error; a hot-reload watcher that stopped

Each message carries the Tesserae module it came from (tess_ui.app, tess_ui.spec.watch), which loguru shows as {name}. A mistake in a view, such as an unknown property or a name no ViewModel has, is an exception that names the file, line and column; the one mistake that is logged instead is the one-way property above.

Failed hot reloads

When a background reload fails, from a TDL error, an unknown widget, or a spec or stylesheet tess_re rejects, Tesserae logs one ERROR line naming the file. The traceback is logged at DEBUG, so a typo doesn't print a stack trace unless you ask for one. The screen stays as it was, and the app and the watcher keep running. A watcher's poll(), which your own loop calls, still raises instead.

Warnings

FontFallbackWarning (from tess_ui.fonts import FontFallbackWarning) is a real Python warning, so warnings.filterwarnings("error", category=FontFallbackWarning) still turns it into an exception. By default, configure_logging also shows warnings through loguru, so they appear in the same format as everything else. Pass capture_warnings=False to leave Python's own warning output alone.

Turning Tesserae's messages off

from loguru import logger

logger.disable("tess_ui")                 # everything from Tesserae
logger.disable("tess_ui.spec.watch")      # just hot reload

logger.enable("tess_ui") turns them back on.